SS 3580 MBTCP Ethernet gateway Modbus TCP - Modbus RTU
General description
The gateway SS3580-MBTCP allows to connect the Modbus RTU devices of a RS-485 network to the Ethernet newtork through the Modbus TCP protocol. By means of the Telnet interface it is possible to configure all the Modbus TCP side options (IP address, subnet mask, etc..) and the Modbus RTU side options (baud rate, etc...).
The device guarantees a full isolation between lines, allowing the use even in the heavy environmental conditions.
SS3000 series devices are designed to be easily mounted on DIN rail, optimizing the space encumbrance. Whereas the thermal dissipation allows it, the devices can be mounted side by side, allowing a relevant reduction of space requiring. The connections are made by means of removable screw terminals, to simiplify the handling of the devices.
LED signalling of Ethernet activity and data rx-tx on the serial line allows a direct monitoring of the system funcionality. The conncetion is made by removable screw-terminals (supply and RS-485) and RJ45 plug (Ethernet).
SS 3580-MBTCP is in compliance with the 89/336/EEC directive on the electromagnetic compatibility.
The device is housed in a rough self-extinguishing plastic container which, thanks to its thin profile of 22.5 mm only, allows a high density mounting on EN-50022 standard DIN rail.
Main features
- Network interface
- Ethernet 10/100Base-T, Modbus TCP
- Telnet configuration
- RJ45 connection
- RS-485 Serial interface
- Modbus RTU Master
- Baud rate up to 115.2 Kbps
- Distance up to 1200 m, up to 32 devices in multipoint
- Removable screw-terminal connection
- LED signalling for Link/Act Ethernet, serial RX-TX, power supply
- Galvanic Isolation on all ways
- EMC compliance – CE mark
- Suitable for DIN rail mounting in compliance with EN-50022
Manuals and guides
Datasheet SS 3580 MBTCP
IOlog series Illustrative leaflet
CE Declaration of Conformity
Compact I/O Modules
Maximum current consumption | 45 mA @ 24 VDC |
---|---|
Communication protocol | Modbus ASCII, Modbus RTU, Modbus TCP (using SS3580 converter) |
Insulation voltage | 1500 Vca @ 50 Hz for 1 minute between inputs, outputs, serial and supply |
EMC Immunity | conform to EN 61000-6-2 |
EMC Emissions | conform to EN 61000-6-4 |
Supply voltage | from 10 to 30 VDC |
Polarity inversion protection | maximum 60 VDC |
Humidity | operating environment from 0 to 90 % (non condensing) |
Storage temperature | from -40 to +85 ºC (without ice) |
Material | self-extinguishing plastic |
Mounting | on EN-50022 DIN rail |
Weight | about 150 g |
Temperature | operating environment from -10 to +60 ºC |